The rack is the unit of compute

How GIGABYTE’s GIGAPOD NVIDIA Vera Rubin NVL72 turns 240 kilowatts (kW) of liquid-cooled infrastructure into a turnkey blueprint for agentic AI

Building the Next Frontier of AI
(Image credit: GIGABYTE)

For most of the past two decades, enterprise infrastructure planning started with the server. Agentic AI breaks that model. Systems that plan tasks, call tools, verify results, and reason across enormous contexts generate token volumes that dwarf traditional chatbots. Indeed, NVIDIA estimates agentic systems consume up to 15 times more tokens than conventional AI applications. Such systems need trillion-parameter models to stay resident in fast memory. Spread such a model across loosely coupled servers, and the network, not the silicon, sets the pace.

That's why the industry now treats the rack, not the server, as the unit of compute. GIGABYTE’s GIGAPOD NVIDIA Vera Rubin NVL72 is built on exactly that premise: a single 240 kW, direct-liquid-cooled rack that behaves like one giant accelerator, delivered pre-integrated and pre-tested from the factory. It targets the hurdles that stall next-generation AI factories: namely memory and bandwidth limits, heat, power delivery, and the months of on-site integration that delay return on investment (ROI).

For chief technology officers (CTOs), chief information officers (CIOs), and infrastructure leaders weighing their next AI build-out, the question is no longer whether rack-scale architecture is coming, but how quickly they can stand it up, cool it, and pay it back. Here's how GIGAPOD answers those questions.

One rack, one giant GPU

GIGAPOD packs 18 GIGABYTE XN16-CB0-L01 compute trays, each a 1 rack unit (1U), 100% liquid-cooled node with two Vera central processing units (CPUs) and four Rubin graphics processing units (GPUs), alongside nine NVLink 6 switch trays. The result is 72 NVIDIA Rubin GPUs and 36 NVIDIA Vera CPUs with 3,168 custom Olympus cores, all in a single rack.

What matters to the business is what those parts become together: one coherent memory domain with 20.7 terabytes (TB) of HBM4 and 1,580 terabytes per second (TB/s) of aggregate bandwidth. Trillion-parameter models, and the large caches that long agentic conversations demand, can live in one place rather than being sliced across servers that spend more time waiting on each other than running compute workloads. The rack is rated for 3,600 petaflops (PFLOPS) of NVFP4 inference.

NVIDIA says the platform delivers inference at one-tenth the cost per million tokens, and trains mixture-of-experts models with one-fourth the GPUs, compared to Blackwell-generation systems. For enterprises, that means more answers per dollar and fewer GPUs to buy for the same workloads.

A fabric built for agents

Agentic AI is communication-heavy. Every reasoning step can trigger exchanges among dozens of GPUs, so interconnect bandwidth decides whether expensive accelerators work or sit idle. Sixth-generation NVLink gives each GPU 3.6 TB/s of bidirectional bandwidth and the rack 260 TB/s of all-to-all bandwidth. That means any GPU can talk to any other at full speed.

Beyond the rack, NVIDIA ConnectX-9 SuperNICs and BlueField-4 data processing units (DPUs) connect to NVIDIA Quantum-X800 InfiniBand or Spectrum-X Ethernet, letting organizations scale out on the fabric that best suits their existing operations. BlueField-4 also offloads security, isolation, and infrastructure services, keeping GPU cycles focused on AI work.

The practical payoff is predictability. When scale-up and scale-out networks are designed together, performance measured in a single rack holds as deployments grow to multiple racks. That's a critical assurance for teams sizing capacity for agentic services that must respond in real time.

Cooling 240 kW without chillers

Rack densities have outrun air cooling. GIGAPOD supports up to 240 kW per rack and captures more than 92% of that heat directly to liquid. Crucially, it runs on warm water with inlet temperatures of up to 45°C, which lets many facilities lose heat without mechanical chillers and drive power usage effectiveness (PUE) as low as 1.06.

Power delivery is engineered just as carefully. Four 3 rack unit (3RU), 110 kW power shelves feed a 54 volts (V) direct current (DC), 5,000 amperes (A) busbar. The rack connects to an in-row coolant distribution unit (CDU). NVIDIA notes that 45°C warm-water cooling can unlock up to 10% more NVL72 racks within the same power budget.

For facilities and operations directors, the takeaway is practical: lower energy bills, simpler retrofits, and a clear, well-documented specification to plan against. That holds, in fact, whether they're upgrading an existing data hall or breaking ground on a greenfield build.

25% more performance in half the space

Floor space and power are now the scarcest resources in the data center. A GIGAPOD scalable unit built on NVIDIA Vera Rubin NVL72 delivers 28,800 PFLOPS of NVFP4 inference across eight compute racks. A comparable GB200 NVL72 unit delivers 23,040 PFLOPS across 16 compute racks.

Do the math: that's 25% more throughput in half the compute rack footprint. That means roughly 2.5 times the inference performance per rack. Fewer racks mean fewer power feeds, fewer cooling loops, less cabling, and less real estate. Best of all, those savings compound into lower total cost of ownership (TCO) over a facility’s entire lifetime.

The same math works in reverse for space-constrained organizations: existing data halls can absorb far more AI capacity before a costly expansion is needed. NVIDIA rates Vera Rubin NVL72 for up to ten times more tokens per megawatt than GB200 NVL72. Thus, the gains extend beyond floor space to the power budget itself, which can be the hardest constraint to relax.

Factory-built, deployed in days

Hardware performance is worthless until it's in production. Traditional rack-scale builds can consume months of on-site cabling, plumbing, and validation. GIGABYTE integrates and validates every GIGAPOD at the factory at both L11 (rack) and L12 (multi-rack cluster) levels. Consequently, systems arrive ready to power on, compressing deployment from months to days and bringing ROI much further forward.

Day-two operations are covered, too. GIGABYTE POD Manager (GPM) provides cluster-scale management, deep telemetry, and orchestration. At the same time, G-REX middleware bridges information technology (IT) and operational technology (OT), monitoring power and cooling in real time and integrating with CDUs through Modbus, Redfish, and REST application programming interfaces (APIs). Together, these tools give operations teams a single, unified view of compute, power, and cooling, so they can spot problems early, keep costly GPUs productive, and run the entire AI factory with fewer surprises.

To see how GIGAPOD fits your AI roadmap, explore GIGABYTE’s NVIDIA Rubin solutions and request an executive technical consultation or a facility readiness audit.